Skip to main content

Proportional-integral electronic water control
V300

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

Simplified access with the master/slave function
Quick and easy to upgrade on site
Centralised timer for managing multiple zones
CIAT concept and design

  • Wall-mounted version with display
  • Flush-mounted version for MAJOR LINE CV and NCV
  • Radiofrequency terminal with repeater
  • Zone timer

The CIAT V300 networked electronic control is designed for use with system-powered comfort units (ductable units, cassettes, AHUs etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

It is available in a water control version with actuation of the 230 V thermo valves in time-proportional mode. The V300 control is available in a factory-fitted, built-in comfort unit with a standard wall-mounting or a low wall-mounting version to be connected by the installer. The V300 control provides a master/slave function to manage the comfort units installed in meeting rooms or large spaces (e.g. open spaces, lobby).

A serial communication bus (3-wire) connects the master unit to its primary slave, then connects the primary slave to the secondary slave, and so on. The master communicates the following information to the slaves: setpoints, air and water temperature, current mode, window switch state. A wall-mounted radio-frequency terminal is available on sites which do not allow wiring (renovation projects etc.). The installation can be managed using a centralised zone timer located in a distribution box.

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.).

  • Master/slave function for managing several comfort units with the same volume (Hall, Reception, Open Space, etc.)
  • 4 operating speeds: comfort / economy / frost protection and off, compliant with article 23 of thermal regulation RT2012 for rooms with intermittent occupancy rates.
  • Eubac certification with optimum control accuracy coefficients for integration in RT calculation engines
  • AA energy efficiency labelling as per eu.bac certification
  • A zone timer to manage comfort units in 6 independent zones
  • Optimized management of HEE motors with a 0-10V signal
  • It integrates into the Hysys offer and into the Comfort pack
  • Its aesthetics and compact dimensions enable easy integration into all types of room
  • Used to make significant savings
  • Simplified access with the master/slave function
  • Easy to use
  • 4 operating modes: complies with RT 2012
  • Quick and easy to upgrade on site
  • Centralized timer for managing multiple zones
  • CIAT concept and design
  • Wall-mounted version with display
  • Flush-mounted version for MAJOR LINE CV and NCV
  • Radiofrequency terminal with repeater
  • Zone timer

The CIAT V300 networked electronic control is designed for use with system-powered comfort units (ductable units, cassettes, AHUs etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

It is available in a water control version with actuation of the 230 V thermo valves in time-proportional mode. The V300 control is available in a factory-fitted, built-in comfort unit with a standard wall-mounting or a low wall-mounting version to be connected by the installer. The V300 control provides a master/slave function to manage the comfort units installed in meeting rooms or large spaces (e.g. open spaces, lobby).

A serial communication bus (3-wire) connects the master unit to its primary slave, then connects the primary slave to the secondary slave, and so on. The master communicates the following information to the slaves: setpoints, air and water temperature, current mode, window switch state. A wall-mounted radio-frequency terminal is available on sites which do not allow wiring (renovation projects etc.). The installation can be managed using a centralised zone timer located in a distribution box.

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.).

  • Master/slave function for managing several comfort units with the same volume (Hall, Reception, Open Space, etc.)
  • 4 operating speeds: comfort / economy / frost protection and off, compliant with article 23 of thermal regulation RT2012 for rooms with intermittent occupancy rates.
  • Eubac certification with optimum control accuracy coefficients for integration in RT calculation engines
  • AA energy efficiency labelling as per eu.bac certification
  • A zone timer to manage comfort units in 6 independent zones
  • Optimized management of HEE motors with a 0-10V signal
  • It integrates into the Hysys offer and into the Comfort pack
  • Its aesthetics and compact dimensions enable easy integration into all types of room
  • Used to make significant savings
  • Simplified access with the master/slave function
  • Easy to use
  • 4 operating modes: complies with RT 2012
  • Quick and easy to upgrade on site
  • Centralized timer for managing multiple zones
  • CIAT concept and design
eu-bac-certification

Certified Eu.bac product

The eu.bac Certification Mark assures users the conformity of our products and systems defined in European directives and European standards.