Skip to main content

Proportional-integral electronic water control
V300

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

Simplified access with the master/slave function
Quick and easy to upgrade on site
Centralised timer for managing multiple zones
CIAT concept and design

  • Wall-mounted version with display
  • Flush-mounted version for MAJOR LINE CV and NCV
  • Radiofrequency terminal with repeater
  • Zone timer

The CIAT V300 networked electronic control is designed for use with system-powered comfort units (ductable units, cassettes, AHUs etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

It is available in a water control version with actuation of the 230 V thermo valves in time-proportional mode. The V300 control is available in a factory-fitted, built-in comfort unit with a standard wall-mounting or a low wall-mounting version to be connected by the installer. The V300 control provides a master/slave function to manage the comfort units installed in meeting rooms or large spaces (e.g. open spaces, lobby).

A serial communication bus (3-wire) connects the master unit to its primary slave, then connects the primary slave to the secondary slave, and so on. The master communicates the following information to the slaves: setpoints, air and water temperature, current mode, window switch state. A wall-mounted radio-frequency terminal is available on sites which do not allow wiring (renovation projects etc.). The installation can be managed using a centralised zone timer located in a distribution box.

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.).

  • Master/slave function for managing several comfort units with the same volume (Hall, Reception, Open Space, etc.)
  • 4 operating speeds: comfort / economy / frost protection and off, compliant with article 23 of thermal regulation RT2012 for rooms with intermittent occupancy rates.
  • Eubac certification with optimum control accuracy coefficients for integration in RT calculation engines
  • AA energy efficiency labelling as per eu.bac certification
  • A zone timer to manage comfort units in 6 independent zones
  • Optimized management of HEE motors with a 0-10V signal
  • It integrates into the Hysys offer and into the Comfort pack
  • Its aesthetics and compact dimensions enable easy integration into all types of room
  • Used to make significant savings
  • Simplified access with the master/slave function
  • Easy to use
  • 4 operating modes: complies with RT 2012
  • Quick and easy to upgrade on site
  • Centralized timer for managing multiple zones
  • CIAT concept and design
  • Wall-mounted version with display
  • Flush-mounted version for MAJOR LINE CV and NCV
  • Radiofrequency terminal with repeater
  • Zone timer

The CIAT V300 networked electronic control is designed for use with system-powered comfort units (ductable units, cassettes, AHUs etc.) in 2-tube, 4-tube, 2-tube + 2 wire applications using recirculated air.

It is available in a water control version with actuation of the 230 V thermo valves in time-proportional mode. The V300 control is available in a factory-fitted, built-in comfort unit with a standard wall-mounting or a low wall-mounting version to be connected by the installer. The V300 control provides a master/slave function to manage the comfort units installed in meeting rooms or large spaces (e.g. open spaces, lobby).

A serial communication bus (3-wire) connects the master unit to its primary slave, then connects the primary slave to the secondary slave, and so on. The master communicates the following information to the slaves: setpoints, air and water temperature, current mode, window switch state. A wall-mounted radio-frequency terminal is available on sites which do not allow wiring (renovation projects etc.). The installation can be managed using a centralised zone timer located in a distribution box.

V300 is a CIAT networked electronic control, designed to control comfort units which are not self-contained (ductable, cassettes, AHU, etc.).

  • Master/slave function for managing several comfort units with the same volume (Hall, Reception, Open Space, etc.)
  • 4 operating speeds: comfort / economy / frost protection and off, compliant with article 23 of thermal regulation RT2012 for rooms with intermittent occupancy rates.
  • Eubac certification with optimum control accuracy coefficients for integration in RT calculation engines
  • AA energy efficiency labelling as per eu.bac certification
  • A zone timer to manage comfort units in 6 independent zones
  • Optimized management of HEE motors with a 0-10V signal
  • It integrates into the Hysys offer and into the Comfort pack
  • Its aesthetics and compact dimensions enable easy integration into all types of room
  • Used to make significant savings
  • Simplified access with the master/slave function
  • Easy to use
  • 4 operating modes: complies with RT 2012
  • Quick and easy to upgrade on site
  • Centralized timer for managing multiple zones
  • CIAT concept and design
eu-bac-certification

Certified Eu.bac product

The eu.bac Certification Mark assures users the conformity of our products and systems defined in European directives and European standards.

Documents

Controls manual

Electrical diagram


Works well with


You may also like