Control module for dehumidification units
CIATpool
Control module for BCP swimming pool dehumidifcation units with scroll compressor.
The CIAT pool control is an electronic module with microprocessor designed for the control and supervision of BCP swimming pool dehumidifcation units.
Different terminal options (user / maintenance)
Multilingual
Numerous configurable features
BMS communication
This control enables unit integration with local supervision solutions: pCO Web (1 unit); BOSS mini (up to 50 units) and BOSS (up to 300 units), as well as with the remote solution.
One model available
Management up to 3 refrigerant circuits and 3 scroll compressors
- Main board for unit with scroll compressor
- Safety pressure switches
- Main board and software configured by CIAT
- pGD1 CONTROL
- Backlit, user-friendly screen
- Screen sized for easy use and extended display of information
- Multilingual
- TCO (instead of PGD1)
- Simple TCO user terminal
- Without access to parameters
- Dehumidification and air conditioning control for swimming pools
- Automatic control of the temperature of the room in accordance with demand for heating and cooling and depending on the optional equipment included (hot water coil, mixing box, electrical heaters, mixing box for free cooling, dual versions)
- Different operating modes: dehumidification in auto, winter or summer mode
- Anti-short-cycle timings
- Water circuit pump control
- Faults diagnosis and general alarm
- Initial programming of the equipment
- Modification of operating parameters
- Alarms displayed on screen
- Variables and sensor values controls displayed on screen
- Adjusting of setpoints
- Optimized operation for dehumidifying with minimum energy consumption
- The control logic is the subject of a patent application
- Mixing box for thermal or thermoenthalpic free cooling and free dehumidification. Optimized management of the introduction of fresh air
- Outlet and return EC plug fans
- Outlet fans and centrifugal return fans with frequency variator
- Auxiliary electrical heaters: one or two stages with On/Off control or one stage with proportional control
- Hot water auxiliary coil with three-way valve with a proportional or an On/Off control
- Activation signal for a possible plate recovery unit outside the machine
- Remote air-cooled condenser control for DUAL operation
- Management of the AERO version
- Air flow controller
- Smoke detection unit
- Refrigerant leak detector
- Possibility to manage fresh air damper based on CO2 levels
- Energy meter
- Operation possible with dual ambient sensor measuring T° + H
- Variety of protocols for BMS with optional communication cards: Carel, ModBus, LonWorks, BACnetTM MSTP, Konnex, BACnetTM Ethernet
One model available
Management up to 3 refrigerant circuits and 3 scroll compressors
- Main board for unit with scroll compressor
- Safety pressure switches
- Main board and software configured by CIAT
- pGD1 CONTROL
- Backlit, user-friendly screen
- Screen sized for easy use and extended display of information
- Multilingual
- TCO (instead of PGD1)
- Simple TCO user terminal
- Without access to parameters
- Dehumidification and air conditioning control for swimming pools
- Automatic control of the temperature of the room in accordance with demand for heating and cooling and depending on the optional equipment included (hot water coil, mixing box, electrical heaters, mixing box for free cooling, dual versions)
- Different operating modes: dehumidification in auto, winter or summer mode
- Anti-short-cycle timings
- Water circuit pump control
- Faults diagnosis and general alarm
- Initial programming of the equipment
- Modification of operating parameters
- Alarms displayed on screen
- Variables and sensor values controls displayed on screen
- Adjusting of setpoints
- Optimized operation for dehumidifying with minimum energy consumption
- The control logic is the subject of a patent application
- Mixing box for thermal or thermoenthalpic free cooling and free dehumidification. Optimized management of the introduction of fresh air
- Outlet and return EC plug fans
- Outlet fans and centrifugal return fans with frequency variator
- Auxiliary electrical heaters: one or two stages with On/Off control or one stage with proportional control
- Hot water auxiliary coil with three-way valve with a proportional or an On/Off control
- Activation signal for a possible plate recovery unit outside the machine
- Remote air-cooled condenser control for DUAL operation
- Management of the AERO version
- Air flow controller
- Smoke detection unit
- Refrigerant leak detector
- Possibility to manage fresh air damper based on CO2 levels
- Energy meter
- Operation possible with dual ambient sensor measuring T° + H
- Variety of protocols for BMS with optional communication cards: Carel, ModBus, LonWorks, BACnetTM MSTP, Konnex, BACnetTM Ethernet
Documents
Controls manual